Hit enter to search or ESC to close
For procurement managers, technical directors and operations leaders sourcing drywall steel profiles, ceiling T-bar grids and light gauge framing components β this guide decodes the factory series 362t125, 400s162, 600s125, 600s162, 600s200 with full gauge 33, 43, 54, 68, 97 thickness mapping, load data and compliance benchmarks for 2026 projects.
β‘ Serving USA, Europe, Middle East, Australia, Southeast Asia since 2003
If you are sourcing ceiling T-bar grids, drywall studs and furring channels from underperforming suppliers, you have likely experienced one or more of these breakdowns:
Inflated pricing. Middlemen add 30β60% margin. You pay for warehouses you never use. Direct factory pricing for 600s162 54 gauge can be 40% lower than trading-company quotes.
Inconsistent gauge / thickness. A β54-gaugeβ T-bar that arrives at 0.40mm instead of 0.54mm causes deflection, sagging and failed inspections.
High shipping costs. Inefficient packing and non-optimized container loads inflate freight by 15β25%. A factory with export experience packs flat T-grids to maximize DDP/CIF value.
Spec ambiguity. Suppliers cannot explain the difference between 362t125, 400s162, 600s125, 600s162, 600s200 or provide load-span tables, coating certificates or fire-resistance data.
Real impact: NIST forensic studies on drop-ceiling failures show that most flat T-grids collapse from disengagement of the cross tee from the main runner β not tensile steel failure. A slight twist in the tab connection can reduce load capacity by 50%. That is an installation-risk you cannot afford. (Source)
Located in Langfang, Hebei, China, Wen'an Jinkai is an integrated, technology-driven manufacturer specializing in ceiling T-bar grids, light steel keels (drywall profiles) and complete framing accessory systems. We were certified under ISO 9001:2008, recognized as a High-Tech Enterprise in 2019, and hold 1 national invention patent, 13 utility model patents, and 1 software copyright.
Our annual output exceeded RMB 100 million in 2012 and RMB 160 million in 2013, with projected turnover above RMB 200 million in 2014 β and growth has continued since. We export to the Middle East, Malaysia, Indonesia, Philippines, Australia and across domestic China.
These factory codes follow a standardized naming logic used in Chinese roll-forming production:
362t125 β 36mm flange/face width, t = track or T-bar main runner, 125mm web depth. Used for main runners in heavy concealed grid systems and drywall partition tracks.
400s162 β 40mm web width, s = stud, 162mm depth. Medium-duty partition stud.
600s125 β 60mm web width, s = stud, 125mm depth. Heavy partition / furring stud.
600s162 β 60mm web width, 162mm depth. Shaft-wall and high-load vertical stud.
600s200 β 60mm web width, 200mm depth. Structural / seismic-rated framing.
Why this matters: The 362t125 400s162 33 combination and the 600s162 43 gauge family are widely specified for South Asian, Middle Eastern and Australian projects. A JIS-aligned approach (referencing Japanese Industrial Standards for steel tolerances) results in higher precision in the roll-forming process, which directly translates to better snap-fit connections and fewer loose joints in the field. (JIS Standards Review)
362t125
Main Tee / Track
400s162
Stud / Cross Tee
600s200
Heavy Structural Stud
In our factory's nomenclature, the numbers 33, 43, 54, 68, 97 refer to the base steel sheet thickness in hundredths of a millimeter:
| Gauge Code | Thickness (mm) | Typical Application | Zinc Coating |
|---|---|---|---|
| 33 | 0.33mm | Light ceiling T-bar grids, non-load-bearing | Z80βZ120 |
| 43 | 0.43mm | Standard T-bar / partition stud | Z120βZ180 |
| 54 | 0.54mm | Commercial partition, ceiling mains | Z180βZ220 |
| 68 | 0.68mm | High-load walls, shaft-wall studs | Z220βZ275 |
| 97 | 0.97mm | Structural fire-rated / seismic framing | Z275+ |
Coastal corrosion study data indicates that standard galvanization (G40) is insufficient for buildings within 5 km of sea water. For the Furring System (Middle East) and Australian Drywall System, we recommend G90 or Z275 coils, especially at weld points where the protective coating is burned off during installation. (NACE Corrosion Evaluation)
Tariff influence: Global trade policies on galvanized steel coil directly affect the cost of drywall steel profiles. The World Steel Association notes that when tariffs rise in North America, manufacturers shift sourcing to Brazil or India β increasing lead times. Our factory stabilizes this by maintaining 60-day coil inventory for the 600s162 54 gauge and 600s200 97 gauge lines. (WorldSteel Global Trade Report)
| Product Code | Profile Type | Flange/Web Width | Depth | Gauge Range | Compliance |
|---|---|---|---|---|---|
| 362t125 | Main Tee / Track | 36mm | 125mm | 33β68 | ISO 9001, CE |
| 400s162 33 | Stud | 40mm | 162mm | 33β54 | ISO 9001, ASTM |
| 600s125 | Stud / Furring | 60mm | 125mm | 43β68 | ISO 9001, AS/NZS |
| 600s162 43 gauge | Shaft Wall Stud | 60mm | 162mm | 43β68 | ISO 9001, BS |
| 600s162 54 gauge | Heavy Stud | 60mm | 162mm | 54β68 | ISO 9001, ASTM |
| 600s162 68 | Structural Stud | 60mm | 162mm | 68β97 | ISO 9001, ASTM C955 |
| 600s162 97 | Fire-Rated Stud | 60mm | 162mm | 97 | ISO 9001, UL |
| 600s200 54 | Structural Stud | 60mm | 200mm | 54β68 | ISO 9001, ASTM |
| 600s200 97 | Seismic / High-Load Stud | 60mm | 200mm | 97 | ISO 9001, UL, CE |
Engineering note: Fire-resistance research on cold-formed steel profiles shows that for the Canada-US Drywall System, the integrity of the drywall lining β not steel thickness alone β is the primary determinant of fire resistance. Furring systems attached to masonry walls create a thermal break that delays heat transfer significantly, and optimizing slot perforations in the stud web can reduce thermal conductivity by up to 15%. (Structural Behavior Study)ποΈ Application Scenarios & Case Results
JIS-aligned tolerances improve snap-fit connections. We supplied 400s162 33 studs and 362t125 tracks for a 30,000 mΒ² hospital project in Malaysia. Result: 0.6% field rework rate vs. the regional 4% benchmark.
Our South American system uses G90 galvanized profiles for moisture-heavy climates. A BogotΓ‘ office tower specified 600s162 68 gauge with Z225 coating, achieving 21% cost saving vs. regional steel suppliers. (AWCI Analysis)
The region is shifting to Australian-system components for superior seismic performance. We delivered 600s162 54 gauge studs with 65mm flange, tested to AS/NZS 4600. Lead time: 3 weeks from order to Shanghai port.
Staggered and double-stud framing is transforming sound isolation. Our UD-150 deep tracks and resilient channels β paired with 600s200 97 gauge studs β raised STC ratings by 12 points in a New York hotel retrofit. (AWCI Acoustic Study)



It refers to a 60mm Γ 162mm drywall stud profile formed from 0.54mm base steel sheet with a specific galvanized coating. It is commonly used for medium-to-high-load partition walls. The β600β indicates the 60mm web width family, βsβ stands for stud, β162β is the profile depth in millimeters, and β54β is the steel thickness in hundredths of a millimeter.
Yes β the 362t125 main runner is designed with compatible slot spacing for both 400mm and 600mm module cross tees. however, we recommend confirming the tab-lock geometry. NIST research shows that FUT-style connections eliminate human-error disengagement, so consider upgrading to FUT profiles for seismic regions.
For orders of 1Γ40HC container (approx. 24β26 tons of profiles), our standard lead time is 15β25 days from confirmed deposit. For mixed SKUs including 600s125, 600s162 68, 600s200 97, lead time is 25β30 days.
Absolutely. We offer custom cut lengths, hole patterns, knockouts, and private-label packaging. Our in-house tooling team has 13 utility model patents and can produce custom roll-forming profiles for your signature system within 10 days after drawing approval.
We provide full commercial invoices, packing lists, Certificate of Origin (CO), bill of lading, plus mill test certificates for the galvanized steel coil. For CE-marked destinations, we supply the CE DoP and EN 14195 test reports. We also provide ISO 9001 quality control documentation upon request.
We perform random sample testing of zinc coating weight using the magnetic thickness gauge method plus the weighing method (ASTM A90). For coastal export projects, we can guarantee Z275 coating with a written test certificate.
Yes. We offer free sample pieces for standard profiles (up to 3 profiles per model, 300mm length) with the buyer covering express shipping. For custom profiles, a small tooling/prototype fee applies, refundable against the first production order.

Ahmed Al-Rashid
Procurement Manager, Dubai, UAE
βWe ordered 600s162 54 gauge studs and 362t125 tracks for a 40-story residential tower. The gauges tested exactly as specified β 0.54mm β and the snap-fit on cross tees was flawless. Installation crew reported zero loose joints across 12,000 mΒ² of ceiling.β

Maria Gonzalez
Technical Director, BogotΓ‘, Colombia
βJinkaiβs South American system with G90 coating has performed excellently in our humid coastal climate. Their 600s162 68 gauge profiles passed our independent salt-spray test with no rust bleed at 500 hours. Shipping cost was 18% lower than our previous Brazilian supplier.β

James Chen
Operations Head, Sydney, Australia
βThe Australian drywall system profiles from Jinkai meet AS/NZS standards and their seismic performance is documented. Their 600s200 97 gauge studs tested 12% above the required load capacity. Plus they helped us optimize container packing β we saved $3,200 per container on freight.β

Kevin Tan
General Contractor, Manila, Philippines
βWeβve used Jinkaiβs FUT grids and flat T-grids T24 for three mall projects. Their quality control is world-class β every batch comes with a factory inspection report. The 400s162 33 furring system performed perfectly under typhoon-class wind loads. Highly recommended.β
See how our sales engineers respond to RFQs β no bots, no delays.

Send us your project specs β we will reply within 24 hours with a line-item quotation, lead time, and available stock for 362t125, 400s162, 600s125, 600s162, 600s200 series in gauge 33β97.
π Your project details remain confidential. Free sample pieces available. Privacy policy applies.

Brandon Wong
Senior International Sales Engineer, Wen'an Jinkai Building Materials Co., Ltd. β 14 years in steel roll-forming and ceiling grid system design.
Brandon has overseen the specification and delivery of 18,000+ tons of T-bar grids and drywall profiles to 20+ countries. His technical articles have been referenced by regional distributors across Southeast Asia and the Middle East. He leads Jinkai's OEM/ODM engineering desk.